<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>金坛市环保设备有限公司 &#187; 填料</title>
	<atom:link href="http://www.jshuanbao.com/tag/%e5%a1%ab%e6%96%99/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.jshuanbao.com</link>
	<description>精心制作 持续发展 创造价值 回馈社会</description>
	<lastBuildDate>Fri, 11 Jun 2010 02:17:42 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.9.1</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>填料式逆流净化塔</title>
		<link>http://www.jshuanbao.com/products/146/</link>
		<comments>http://www.jshuanbao.com/products/146/#comments</comments>
		<pubDate>Thu, 11 Feb 2010 03:14:05 +0000</pubDate>
		<dc:creator>阿正</dc:creator>
				<category><![CDATA[产品展示]]></category>
		<category><![CDATA[净化塔]]></category>
		<category><![CDATA[喷淋]]></category>
		<category><![CDATA[填料]]></category>
		<category><![CDATA[处理]]></category>
		<category><![CDATA[废气]]></category>
		<category><![CDATA[酸雾]]></category>

		<guid isPermaLink="false">http://www.jshuanbao.com/products/146/</guid>
		<description><![CDATA[产品名称： 　　填料式逆流净化塔
产品概述： 　　废气净化塔是一种常用的废气净化处理装置，其基本原理是利用气体与液体间的接触，将气体中的污染物传送到液体中，然后再将清洁之气体与被污染的液体分离，达成清净空气的目的。 　　金坛市环保设备有限公司制造的JHT型净化塔是一种气液两相逆流式传质的填料式处理塔，由塔体、泵喷淋系统、引风机、水箱等部件组成，接触气液的塔体均采用聚丙烯（PP）塑料制作而成，可使用于SO2、NOx、氢氟酸、盐酸酸雾等废气的吸收处理。具有净化效率高、结构紧凑、耐腐蚀、重量轻、维修方便等优点。
产品原理 　　废气经由填充式洗涤塔，采用气液逆向吸收方式处理，即液体自塔顶向下以雾状（或小水滴）喷洒而下。废气则由塔底（逆向流）达到气液接触之目的。此处理方式，可起到冷却废气温度、气体调理、及颗粒去除的作用。经过处理后的气体经过除雾段处理后排入大气中。 　　气流进入净化塔，其中的有害成分与喷淋洗涤液充分接触之后，液滴或液膜扩散附於气流粒子上，或者增湿於粒子，使粒子借着重力、惯性力等作用达到分离去除之目的。气态污染物质则借着紊流、分子扩散等质量传送以及化学反应等现象传送入洗涤液体中达到与进流气体分离之目的。并可在洗涤液中添加化学物质，以化学反应方式吸收控制气体中的有害物质。
性能特点： 　　１. 使用范围广。化工、轻工、印染、医药、钢铁、机械、电子、仪表、电镀等工业企业生产过程中排放的SO2、NOx、HF、甲醛等废气，采用本设备，都可以得到满意的效果。 　　２. 净化效率高。采用二级逆向喷淋，填料比面积大，性能稳定，对各种浓度的酸性废气净化率均可达到85%~95%。 　　３. 设备阻力小，在保证足够气液接触面积基础上，选用空气动力特性最佳的填料品种及结构形式，方便需用耐腐蚀低压通风机。 　　４.占地面积小。该废气净化塔集塔体、吸收槽、循环泵与一体。结构紧凑。安装方便，操作方便。
JHT型净化塔外形规格及技术指标



型号
处理风量(M3/h)
塔径(mm)
塔高(mm)
配套风机
配套水泵


JHT-17
3000
1700
4000
4-72.3A（C）
YLX1-20


JHT-20
6200
2000
4500
4-72.5C
YLX1-30


JHT-22
10000
2200
5000
4-72.6C
YLX1-40


JHT-25
15000
2500
5500
4-72.8C
FS80-65-170-5.5


JHT-27
24000
2700
5800
4-72.10C
FS80-65-170-5.5


JHT-30
35000
3000
5800
4-72.12D（C）
FS80-65-170-7.5



]]></description>
			<content:encoded><![CDATA[<p><strong>产品名称：</strong> <br/>　　填料式逆流净化塔</p>
<p><strong>产品概述：</strong> <br/>　　废气净化塔是一种常用的废气净化处理装置，其基本原理是利用气体与液体间的接触，将气体中的污染物传送到液体中，然后再将清洁之气体与被污染的液体分离，达成清净空气的目的。 <br/>　　金坛市环保设备有限公司制造的JHT型净化塔是一种气液两相逆流式传质的填料式处理塔，由塔体、泵喷淋系统、引风机、水箱等部件组成，接触气液的塔体均采用聚丙烯（PP）塑料制作而成，可使用于SO2、NOx、氢氟酸、盐酸酸雾等废气的吸收处理。具有净化效率高、结构紧凑、耐腐蚀、重量轻、维修方便等优点。</p>
<p><strong>产品原理</strong> <br/>　　废气经由填充式洗涤塔，采用气液逆向吸收方式处理，即液体自塔顶向下以雾状（或小水滴）喷洒而下。废气则由塔底（逆向流）达到气液接触之目的。此处理方式，可起到冷却废气温度、气体调理、及颗粒去除的作用。经过处理后的气体经过除雾段处理后排入大气中。 <br/>　　气流进入净化塔，其中的有害成分与喷淋洗涤液充分接触之后，液滴或液膜扩散附於气流粒子上，或者增湿於粒子，使粒子借着重力、惯性力等作用达到分离去除之目的。气态污染物质则借着紊流、分子扩散等质量传送以及化学反应等现象传送入洗涤液体中达到与进流气体分离之目的。并可在洗涤液中添加化学物质，以化学反应方式吸收控制气体中的有害物质。</p>
<p><strong>性能特点：</strong> <br/>　　１. 使用范围广。化工、轻工、印染、医药、钢铁、机械、电子、仪表、电镀等工业企业生产过程中排放的SO2、NOx、HF、甲醛等废气，采用本设备，都可以得到满意的效果。 <br/>　　２. 净化效率高。采用二级逆向喷淋，填料比面积大，性能稳定，对各种浓度的酸性废气净化率均可达到85%~95%。 <br/>　　３. 设备阻力小，在保证足够气液接触面积基础上，选用空气动力特性最佳的填料品种及结构形式，方便需用耐腐蚀低压通风机。 <br/>　　４.占地面积小。该废气净化塔集塔体、吸收槽、循环泵与一体。结构紧凑。安装方便，操作方便。</p>
<p><strong>JHT型净化塔外形规格及技术指标</strong></p>
<table>
<tbody>
<tr>
<th width="50" height="19">型号</th>
<th width="72">处理风量(M<sup>3</sup>/h)</th>
<th width="40">塔径(mm)</th>
<th width="32">塔高(mm)</th>
<th width="89">配套风机</th>
<th width="105">配套水泵</th>
</tr>
<tr>
<td height="19">JHT-17</td>
<td align="right">3000</td>
<td align="right">1700</td>
<td align="right">4000</td>
<td>4-72.3A（C）</td>
<td>YLX1-20</td>
</tr>
<tr>
<td height="19">JHT-20</td>
<td align="right">6200</td>
<td align="right">2000</td>
<td align="right">4500</td>
<td>4-72.5C</td>
<td>YLX1-30</td>
</tr>
<tr>
<td height="19">JHT-22</td>
<td align="right">10000</td>
<td align="right">2200</td>
<td align="right">5000</td>
<td>4-72.6C</td>
<td>YLX1-40</td>
</tr>
<tr>
<td height="19">JHT-25</td>
<td align="right">15000</td>
<td align="right">2500</td>
<td align="right">5500</td>
<td>4-72.8C</td>
<td>FS80-65-170-5.5</td>
</tr>
<tr>
<td height="19">JHT-27</td>
<td align="right">24000</td>
<td align="right">2700</td>
<td align="right">5800</td>
<td>4-72.10C</td>
<td>FS80-65-170-5.5</td>
</tr>
<tr>
<td height="19">JHT-30</td>
<td align="right">35000</td>
<td align="right">3000</td>
<td align="right">5800</td>
<td>4-72.12D（C）</td>
<td>FS80-65-170-7.5</td>
</tr>
</tbody>
</table>
]]></content:encoded>
			<wfw:commentRss>http://www.jshuanbao.com/products/146/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>生物填料的选用与设计</title>
		<link>http://www.jshuanbao.com/tech/102/</link>
		<comments>http://www.jshuanbao.com/tech/102/#comments</comments>
		<pubDate>Wed, 13 May 2009 02:03:00 +0000</pubDate>
		<dc:creator>dmuentironment</dc:creator>
				<category><![CDATA[技术资讯]]></category>
		<category><![CDATA[填料]]></category>
		<category><![CDATA[生物]]></category>
		<category><![CDATA[设计]]></category>
		<category><![CDATA[选用]]></category>

		<guid isPermaLink="false">http://www.jshuanbao.com/tech/102/</guid>
		<description><![CDATA[（一）普通生物滤池设计负荷： 　　当处理以生活污水为主的城市污水时，有机负荷N（kg/m3.d）根据当地年平均气温可分别选择 0.1kg/m3·d（气温3~6℃），0.17kg/m3·d（气温6~10℃），0.2kg/m3·d（气温&#62;10℃）。滤池体积V及面积A下式计算：

　　H：滤池的滤料厚度，即滤池的有效深度，对于生活污水可取2m。 　　S0：滤池进水的有机物浓度，mg/L 　　Q：流入滤池的污水设计流量，m3/d，一般采用平均流量，若流量小或变化大时，采用最高流量。水力负荷一般在1-3m3/m2·d。
（二）高负荷生物滤池设计负荷： 　　处理城市污水时，在正常气温下，表面水力负荷以滤池面积计，宜为10~30m3/m2·d；五日生化需氧量容积负荷以填料体积计，不宜大于1.2kg/m3·d。滤层高度2m。进水的BOD5应小于200mg/L，否则需要采用回流处理水的措施。
（三）塔式生物滤池设计负荷： 　　滤层总厚度一般宜为8-12m；每层高度不宜超过2.5m；水力负荷80-200m3/m2·d，BOD容积负荷1.0-2.0kg/m3·d。 进水的BOD5宜控制在500mg/L以下，否则应采用处理水回流措施。当进水BOD5在250mg/L时，填料总高度为8m，进水BOD5每增加50mg/L直至500mg/L时，填料高度增加2m。
（四）接触氧化工艺 　　池体总高度一般为4.5-5.0m，其中填料高度为2.0-3.5m，底部布气层高度为0.6-0.7m，顶部稳定水层为0.5-0.6m。
　　BOD5容积负荷： 　　　　国内：当处理生活污水（或以生活污水为主的城市污水）或处理印染废水时，Nw=3.0-4.0kg/m3·d和1.0-2.0kg/m3·d； 城市污水处理排放标准要求BOD5分别为30mg/L和10mg/L时，的取值分别为5.0 kg/m3·d和2.0kg/m3·d； 　　　　国外：当城市污水二级处理时，Nw=1.2-2.0kg/m3·d，当处理水BOD5要求达到30mg/L以下时,=0.8kg/m3·d；当进行三级处理时，=0.12-0.18kg/m3·d；当要求处理水BOD5要求达到10mg/L以下时，=0.2kg/m 3·d。接触氧化池内溶解氧量一般维持在2.5-3.5mg/L，气水比为15:1-20:1。采用穿孔管曝气时，曝气风管干管风速10-15m/s，支管4-5m/s。在使用生物填料时，填料的充填率根据接触氧化工艺的不同，充填率一般为30~60%。
]]></description>
			<content:encoded><![CDATA[<p><span style="COLOR: #ff0000"><strong>（一）普通生物滤池设计负荷：</strong></span> <br/>　　当处理以生活污水为主的城市污水时，有机负荷N（kg/m<sup>3</sup>.d）根据当地年平均气温可分别选择 0.1kg/m<sup>3</sup>·d（气温3~6℃），0.17kg/m<sup>3</sup>·d（气温6~10℃），0.2kg/m<sup>3</sup>·d（气温&gt;10℃）。滤池体积V及面积A下式计算：</p>
<p><a href="http://jshuanbao.com/images/jthb/swtl.png" title="swtl.png"><img src="http://jshuanbao.com/images/jthb/zrtn_001n27a5b281_tn.jpg" alt="swtl.png" height="59" border="0" width="316"/></a></p>
<p>　　H：滤池的滤料厚度，即滤池的有效深度，对于生活污水可取2m。 <br/>　　S<sub>0</sub>：滤池进水的有机物浓度，mg/L <br/>　　Q：流入滤池的污水设计流量，m<sup>3</sup>/d，一般采用平均流量，若流量小或变化大时，采用最高流量。水力负荷一般在1-3m<sup>3</sup>/m<sup>2</sup>·d。</p>
<p><span style="COLOR: #ff0000"><strong>（二）高负荷生物滤池设计负荷：</strong></span> <br/>　　处理城市污水时，在正常气温下，表面水力负荷以滤池面积计，宜为10~30m<sup>3</sup>/m<sup>2</sup>·d；五日生化需氧量容积负荷以填料体积计，不宜大于1.2kg/m<sup>3</sup>·d。滤层高度2m。进水的BOD5应小于200mg/L，否则需要采用回流处理水的措施。</p>
<p><span style="COLOR: #ff0000"><strong>（三）塔式生物滤池设计负荷：</strong></span> <br/>　　滤层总厚度一般宜为8-12m；每层高度不宜超过2.5m；水力负荷80-200m<sup>3</sup>/m<sup>2</sup>·d，BOD容积负荷1.0-2.0kg/m<sup>3</sup>·d。 进水的BOD5宜控制在500mg/L以下，否则应采用处理水回流措施。当进水BOD5在250mg/L时，填料总高度为8m，进水BOD5每增加50mg/L直至500mg/L时，填料高度增加2m。</p>
<p><strong><span style="COLOR: #ff0000">（四）接触氧化工艺</span></strong> <br/>　　池体总高度一般为4.5-5.0m，其中填料高度为2.0-3.5m，底部布气层高度为0.6-0.7m，顶部稳定水层为0.5-0.6m。</p>
<p>　　BOD5容积负荷： <br/>　　　　国内：当处理生活污水（或以生活污水为主的城市污水）或处理印染废水时，Nw=3.0-4.0kg/m<sup>3</sup>·d和1.0-2.0kg/m<sup>3</sup>·d； 城市污水处理排放标准要求BOD5分别为30mg/L和10mg/L时，的取值分别为5.0 kg/m3·d和2.0kg/m<sup>3</sup>·d； <br/>　　　　国外：当城市污水二级处理时，Nw=1.2-2.0kg/m<sup>3</sup>·d，当处理水BOD5要求达到30mg/L以下时,=0.8kg/m<sup>3</sup>·d；当进行三级处理时，=0.12-0.18kg/m<sup>3</sup>·d；当要求处理水BOD5要求达到10mg/L以下时，=0.2kg/m <sup>3</sup>·d。接触氧化池内溶解氧量一般维持在2.5-3.5mg/L，气水比为15:1-20:1。采用穿孔管曝气时，曝气风管干管风速10-15m/s，支管4-5m/s。在使用生物填料时，填料的充填率根据接触氧化工艺的不同，充填率一般为30~60%。</p>
]]></content:encoded>